Product support

Alia 4 in 1 Boiling and Chilled setup and installation

Everything your experienced licensed plumber needs to install the Alia 4 in 1 Boiling and Chilled, from the space under your sink to the first pour.

Alia 4-in-1 boiling and chilled tap system diagram showing the tap, filter and under-sink units

Before you start

Check your space

How the system fits together

This is your system as it sits in the cabinet under your sink. Each installation step below picks out the part it's about.

Turn it around in 3D

Drag to turn the Alia 4 in 1 Boiling and Chilled system, and pinch or scroll to zoom in. On a phone you can also see it in your own room with the AR button.

The installation schematic

This is the drawing your plumber works from. The hose numbers 1 to 6 match Alia's installation guide, in the downloads below.

Cabinet space

Leave a clear space 500mm wide, 580mm deep and 450mm high inside the cabinet under your sink.

Keep room around the units for air and for changing the filter. Place the units close to the tap, so the hoses stay short and don't twist.

Power

You need two powerpoints under the sink, one each for the Bollente and the Chilled Stream.

Each unit plugs into its own earthed, switched powerpoint. Don't use a double adaptor or an extension lead.

The Bollente needs power all the time, so leave its powerpoint on. If there is no powerpoint yet, a licensed electrician must fit one before installation day.

Water

Your plumber connects the tap to your hot and cold water, and the filtered water system to the cold supply.

  • Fit the Alia pressure limiting valve that comes with the system, on the cold supply. You must fit it even if your home already has one, in case your home's valve fails.
  • Only connect the system to mains water that is safe to drink. Don't connect it to rainwater from a tank, or to water that is microbiologically unsafe.

In the box

What comes with your system

  • 4 in 1 tap
  • Bollente boiling unit, with its plug
  • Chilled Stream chilling unit, with its tubes
  • F5000L filter
  • Pressure limiting valve
  • Inlet and outlet connectors, 3/8" BSP to silicone and 3/8" BSP to 1/2" BSP

Tools your plumber needs

  • Tape measure
  • Adjustable spanner
  • Thread-seal tape
  • Sharp tube cutter for plastic hoses

Installation steps

Tap and filter

Step 1. Mount the tap

Fit the tap to the benchtop with the mounting parts packed with it, and follow the fitting instructions that come with the tap. Its base is 45mm across and it uses an M34 × 1.5 thread. It needs a 35mm hole in the benchtop.

Feed its hoses down into the cabinet without twisting them.

Step 2. Fit the pressure limiting valve

Fit the Alia pressure limiting valve to the cold stop tap. Check its O-ring is seated before you tighten it. Don't rely on a valve that's already in your home.

If your mains pressure is above 500 kPa, the Bollente manual asks for a pressure reducing valve on the cold mains inlet. Your plumber can check this.

Step 3. Mount the filter head

Fix the filter head where you can reach it to change the cartridge, with its carriage facing down.

Wrap both threads with thread-seal tape and fit the two grey connectors. Tighten them by hand, then finish with a spanner. Don't over-tighten, or the O-ring or the plastic fitting can crack.

Water flows through the filter one way only. Follow the arrow on the head, from in to out.

Step 4. Connect the tap hoses

Connect hose 2 to the hot stop tap and hose 1 to the T-piece on the pressure limiting valve. These two feed the mixer lever.

From the T-piece, run a line to the inlet side of the filter. From the filter outlet, run hose 3 up to the tap, and a line to Water In on the Chilled Stream.

Step 5. Fit the filter cartridge

Slide the filter into its cradle and take the cap off the cartridge. Push it into the head and turn it clockwise until it locks.

Write today's date on the label, so you know when it's due for a change.

Under-sink units

Step 6. Place the Bollente

Stand the Bollente upright and level, close to the tap. Check the hoses reach it without twisting and the plug reaches its powerpoint without stretching.

Leave 50–100mm of air at each side and about 25mm at the back. Keep the display at the front, where you can reach it.

Step 7. Place the Chilled Stream

Stand the Chilled Stream level, with space around it for air. It gives off heat, so the cabinet needs a vent. Without one, its manual asks you to keep the cabinet door open while it runs. A large cabinet with plenty of space around the Chilled Stream doesn't need a vent.

Take the blue clips and covers off Water In and Water Out. Water In comes from the filter. Water Out goes to the tap.

Connect the water

Step 8. Connect the chilled line

Run hose 4 from Water Out on the Chilled Stream up to the tap.

Step 9. Connect the Bollente

The Bollente's inlet and outlet are both 3/8" BSP male threads. Fit the right connectors to the tap hoses and tighten them gently with a spanner.

Run hose 5 from the tap to the blue inlet and hose 6 from the red outlet back to the tap.

Fill, test and switch on

Step 10. Flush the filter

Turn on the water. Turn the left handle towards you and run chilled water for 60 seconds. This flushes the filter and fills the Chilled Stream.

Then run the mixer lever, so water reaches the tap.

Step 11. Fill the Bollente

Press and hold the safety button and turn the left handle away from you. Hold it until water flows steadily from the spout. It takes about 90 seconds, and it means the Bollente is full.

Step 12. Check for leaks before power

Let go of the handle and check every connection point. Tighten any that leaks, then fill and check again before you plug anything in.

Step 13. Switch on the Bollente and the Chilled Stream

Make sure the cabinet is dry. Plug the Bollente into its powerpoint and switch it on. Hold its power button for 3 to 4 seconds, choose a temperature with SET and confirm with OK.

It's set to 98°C by default. If the water seems to boil all the time, lower the setting to 95°C.

Plug in and switch on the Chilled Stream. Run chilled water for five minutes to flush it, and don't drink it until it's flushed. Within 15 minutes the water should start to get colder.

Step 14. Final check and handover

With everything running, check every connection point once more. Make sure the install date is on the filter label.

Show the household how the safety button works for boiling water.

Specifications

4 in 1 tap dimensions

From Alia's 4 in 1 drawing. All sizes are in millimetres. Drill a 35mm hole in the benchtop for the tap.

System at a glance

PartDetail
Tap397.3mm high, 200mm reach, 230.4mm from the benchtop to the outlet
Tap base and thread45mm base, M34 × 1.5 thread
Benchtop hole35mm
Bollente boiling unit195mm wide, 200mm deep, 295mm high. 2.4 L tank, up to 1.6 L per pour, 1600 W
Boiling temperatureSeven settings from 35°C to 98°C, set to 98°C by default
Chilled Stream140mm wide, 350mm deep, 310mm high
Chilled water8–12°C
FilterF5000L, 5-micron activated carbon block. Change it every 8–12 months
PowerpointsTwo, one per unit
Cabinet space500mm wide, 580mm deep, 450mm high inside
Pressure limiting valve500 kPa, supplied
Models coveredAG-CS-R41BG, AG-CS-R41NI, AG-CS-R41MB, AG-CS-R41GM

Downloads

Still need help?

Call or email our team. Have your model and proof of purchase handy.