Where everything is
The stop taps, the filter and each unit's powerpoint are under your sink. Use this picture to find them.
Taps that pour filtered boiling, chilled or sparkling water.
A toilet with an integrated bidet, heated seat and warm air dryer.
Round and rectangular basins that sit on top of the vanity.
For Alia owners. Upgrade kits, taps sold on their own, filter cartridges and CO₂.
Filtered boiling and chilled water, plus normal hot and cold, from one tap.
See all boiling & chilled water tapsFiltered boiling, chilled and sparkling water from one tap.
See all sparkling water tapsTwo-bowl stainless steel sink with a built-in cup washer and pull-out mixer.
See the Smart SinkProduct support
Answers to common questions about the Alia X51 Boiling and Ambient, what each fault code means and how to reach our team.
The stop taps, the filter and each unit's powerpoint are under your sink. Use this picture to find them.
The water in the tank is boiling. Pour a little water off, then lower the setting on the Bollente by 1–2°C.
Check the aerator at the end of the spout isn't blocked. If it keeps happening, your plumber can bleed the air from the system and refill it.
Check the Bollente is plugged in, its powerpoint is on and its display is lit. If the display stays dark, check the safety switch in your switchboard.
Then press the power button for 4 seconds to switch it on, choose a temperature with SET and confirm with OK.
That's normal. The Bollente isn't under pressure, a safety design, so the water takes a moment to start. After a large pour, the pause is a little longer.
Very small pours can leave water in the expansion chamber. Pour about 200mL, around one cup, to clear it, and avoid pours under 100mL, a little under half a cup.
If it still drips, the aerator at the end of the spout may be blocked. Remove it and clean it.
The filter is probably due for a change. Change it every 8–12 months. The steps are on the operation and maintenance page.
Or a stop tap could be partly closed. Check each one is fully open.
Check the stop taps under the sink are open and no hose is twisted or kinked. Then remove and clean the aerator at the end of the spout.
Still nothing? Call us on (03) 9219 0189. Your plumber may need to flush the lines.
E3 means the tank is empty, so the heater won't switch on. This protects the unit.
Switch the Bollente off at its power button. Hold the padlock for 2 seconds, then hold the red boiling button until water flows steadily. Switch the Bollente on again.
If you leave it, the Bollente switches itself off after about 5 minutes until it's refilled.
Change the filter if it's been 8–12 months. After a few days away, run the filtered water for 30 seconds before you drink it.
Check the X51 control box under the sink is plugged in and its powerpoint is on.
For boiling water, hold the padlock for 2 seconds, let go, then hold the red boiling button before it locks again.
Turn off the stop taps and switch off each unit at its powerpoint. Dry the area and look for the wet connection point.
Call your plumber to fix it, and call us on (03) 9219 0189 if a part needs replacing.
Codes show on the unit's display under the sink.
| Code | Unit | What it means | What to do |
|---|---|---|---|
| E3 | Bollente | The tank is empty, so the heater won't start | Switch it off, refill it from the tap and switch it on again |
Every Alia product is covered by a 2-year warranty. Keep your proof of purchase.
To stay covered, a licensed plumber must install it with the Alia pressure limiting valve. Keep it from freezing, and only let an authorised technician open a unit.
Read the full warranty policy.
Call (03) 9219 0189 or email sales@aliaglobal.com.au. Tell us your model and have your proof of purchase handy. A photo of the setup under your sink helps us help you.
Nothing matches that search. Our team can help on (03) 9219 0189
Call or email our team. Have your model and proof of purchase handy.