What the kit does

The kit adds chilled and sparkling water to an Alia X51 Boiling and Ambient tap that is already installed. The Fizz-X unit and a CO₂ cylinder go in the cabinet under your sink.

Your tap, its finish and your benchtop stay as they are. Once the kit is fitted, your system matches the Alia X51 Boiling, Chilled and Sparkling.

What comes in the kit

  • Fizz-X chilled and sparkling unit, with its power cord, four PE tubes, two insulation sleeves and four quick-connect switches
  • Alia CO₂ cylinder, 2.2 L, food grade
  • CO₂ regulator, with two gauges

Your X51 tap, X51 control box, Bollente and F5000L filter stay in place.

Which tap it fits

Only the Alia X51 Boiling and Ambient tap. On your invoice, its model code starts with AG-BX.

It doesn't fit an Alia 4 in 1 tap. The 4 in 1 can't pour sparkling water.

Before your plumber starts

Cabinet space

The upgraded system needs a clear space 700mm wide, 580mm deep and 450mm high inside the cabinet. That is 200mm wider than the 500mm your system needs today.

The Fizz-X is 230mm wide, 400mm deep and 340mm high. The CO₂ cylinder is 397mm high and 110mm wide.

Keep room to reach the CO₂ cylinder and the filter for changes. A cabinet without a middle shelf gives your plumber the most room.

Power

The upgraded system needs three powerpoints under the sink, one each for the X51 control box, the Bollente and the Fizz-X. That is one more than you have now.

The Fizz-X plugs into its own earthed, switched powerpoint. Don't use a double adaptor or an extension lead.

If there is no spare powerpoint, a licensed electrician must fit one before installation day.

Fitting the kit

Your system after the upgrade

This is how the system sits in the cabinet once the kit is in. The Fizz-X and the CO₂ cylinder are the new parts. Everything else is already under your sink.

Step 1. Place the Fizz-X

Stand the Fizz-X level, with about 50mm of air around it. It gives off heat, so the cabinet needs a vent. Without one, the Fizz-X manual asks you to keep the cabinet door open while it runs. A large cabinet with plenty of space around the Fizz-X doesn't need a vent.

Keep the Fizz-X where the water coming in and the air around it stay between 10°C and 38°C, the range its manual gives.

Press the grey collet on each port and pull out the shipping plugs.

Step 2. Stand the CO₂ cylinder

Stand the CO₂ cylinder upright beside the Fizz-X, in a well-ventilated spot. Take the protection cap off its valve and connect the regulator to the valve.

Connect the CO₂ gas line to the yellow CO₂ port on the Fizz-X.

Turn the regulator's black knob clockwise until the needle on the right-hand gauge sits at 4 bar, the red line.

Step 3. Connect the chilled and sparkling lines

On your system today, one line runs from the filter outlet to IN on the control box.

From the filter outlet, fit a T-piece. Run one line to IN on the control box and one to Water In on the Fizz-X.

Run the chilled and the sparkling lines from the Fizz-X to the control box. Follow the arrows on the back of the control box, which show which way the water flows.

Refit every C locking clip.

Step 4. Check for leaks before power

Check every clip is in and the cabinet is dry. Turn the water back on and check every connection point.

Step 5. Fill the chilled and sparkling lines

Plug the X51 control box back in and switch it on. Run water from the blue button until a steady stream flows. If the panel doesn't respond, unlock it first.

Plug in the Fizz-X and hold its power button for 2 to 3 seconds to switch it on. Then run sparkling water from the green button for one minute, to flush the sparkling line before anyone drinks from it.

Step 6. Switch the Bollente back on

Plug the Bollente back in and switch on its powerpoint. Check its display is lit.

If the display is dark, hold the power button for 3 to 4 seconds. Choose a temperature with SET and confirm with OK.

Step 7. Final check and handover

With everything running, check every connection point once more. The Fizz-X takes about 40 minutes to chill the first time.

Show the household that the blue button now pours chilled water and the green button pours sparkling water.

After the upgrade

What changes, and what stays the same

What changesBeforeAfter
Boiling water35–98°C, filteredNo change
Blue button on the panelFiltered ambient waterChilled water, 8–12°C
Green button on the panelNot usedSparkling water, with a fizz you can adjust
Mixer leverHot and cold water from the mainsNo change
Cabinet space500mm wide700mm wide
PowerpointsTwoThree

Pour chilled and sparkling water

Use the green button for sparkling water and the blue button for chilled water. The green button is already on your tap. It starts working once the Fizz-X is connected.

Only sparkling water uses CO₂. Chilled and boiling water pour still.

Set the fizz

The regulator on top of the CO₂ cylinder sets how much CO₂ reaches the Fizz-X. Your plumber sets it so the right-hand gauge reads 4 bar, the red line. Turn the knob to choose a lighter or a stronger fizz.

The left-hand gauge shows how much CO₂ is left in the cylinder. When its needle reaches the red zone, it's time for a new cylinder.

Troubleshooting

The chilled water isn't cold yet

After you first switch it on, the Fizz-X takes about 40 minutes to chill. After heavy use, it needs about 20 minutes to cool down again.

Check the Fizz-X has air around it and its vents are clear.

The sparkling water is flat or weak

Check the regulator needle is at 4 bar, the red line. If the fizz keeps getting weaker, the CO₂ cylinder is running low. One lasts around 6–8 months in a typical home, so it may be time for a new one.

E0The Fizz-X shows E0

The water is off or the pressure is too low. Check the stop tap is open and your mains water is on.

E1The Fizz-X shows E1

A temperature sensor connection needs checking. Switch the Fizz-X off and call us on (03) 9219 0189. Don't open the unit.

There's water under the sink

Turn off the stop taps and switch off each unit at its powerpoint. Dry the area and look for the wet connection point.

Call your plumber to fix it, and call us on (03) 9219 0189 if a part needs replacing.

Warranty and help

Your warranty

Your kit is covered by Alia's 2-year warranty, like every Alia product. Keep your proof of purchase.

Don't open, modify or repair a unit yourself. It's unsafe and it voids your warranty. Read the full warranty policy.

Downloads

Still need help?

Call or email our team. Have your model and proof of purchase handy.